Skip to content
#

workflows

Here are 410 public repositories matching this topic...

longquanzheng
longquanzheng commented Feb 5, 2021

Is your feature request related to a problem? Please describe.
Need to search using LIKE operator with search attributes? eg, WorkflowType LIKE workflowType-prefix.*
Right now the workflowType is using keyword type for performance reason so it doesn't support wildcard search.

https://www.elastic.co/guide/en/elasticsearch/reference/current/keyword.html

keyword fields are untokeniz
appsmith
RakshaKShetty
RakshaKShetty commented Jun 22, 2021

Description

[What happened]Specific to windows->In text widget ->for enable scroll-> even when its enabled or disabled when the text is too big the scroll is displayed

Steps to reproduce the behaviour:

Add steps to reproduce this behaviour, include console / network logs & screenshots

  1. Go to widgets
  2. Drag and drop the text widget
  3. In the text add the Paragraph
  4. Don't
wfgydbu
wfgydbu commented Feb 5, 2021

SUMMARY

I just faced an embarrassed problem that command st2 action list keeps return 503.

I tried st2 --debug action list and the result in line HTTP_PROXY(uppercase) was empty. This mislead me that the proxy info was set(which is not).

I finally found that the root cause is a lowercase http_proxy env variable was set in the system.

So I think it maybe more friend

elsa-core
onepanel

The open and extensible end-to-end computer vision platform with built-in modules for model building, automated labeling, data processing, model training, hyperparameter tuning, workflow orchestration and serverless inference.

  • Updated May 25, 2021
  • Go
odin
ttymck
ttymck commented Aug 2, 2020

Describe the bug
Deploying a new job, then pulling logs via the CLI results in a panic (SIGSEGV).

To Reproduce

  1. odin deploy -f test.job.yaml
  2. odin log -i {job_id}
vagrant@vagrant:~/odin$ odin log -i dea194794589
panic: runtime error: invalid memory address or nil pointer dereference
[signal SIGSEGV: segmentation violation code=0x1 addr=0x40 pc=0x79c764]

goroutine
gh-action-pypi-publish
aiida-core
mbercx
mbercx commented May 10, 2021

Is your feature request related to a problem? Please describe

When I first wanted to obtain the entry point from a Group instance, I intuitively looked for the entry_point attribute. However, it seems that the entry point of a Group type can be obtained with the type_string attribute instead. Is there a difference between the type_string and the entry point? If not, perhaps we can

Improve this page

Add a description, image, and links to the workflows topic page so that developers can more easily learn about it.

Curate this topic

Add this topic to your repo

To associate your repository with the workflows topic, visit your repo's landing page and select "manage topics."

Learn more