Skip to content
#

iot

Here are 11,645 public repositories matching this topic...

netdata
HolgerHees
HolgerHees commented May 17, 2019

Hi,

first thanks for this awesome software. But I have some trouble and I don't know how to proceed. First I try to find out what else I could provide for this report to be a good bug report.

First, I use the latest version (v1.14.0) from openSUSE build Service. I know, I should compile it by my self to avoid any other causes for this behavior. But for now I still use this package from there

joshkping
joshkping commented Nov 16, 2021

Is there an existing issue for this?

  • I have searched the existing issues

Kong version ($ kong version)

2.5.1.0

Current Behavior

When calling kong.response.exit(), the function automatically sets the Content-Length header on the response even if the Transfer-Encoding header is present. This is in violation of RFC 7230 3.3.2:

A sender MUST NOT send a Content-

Aries-Lee1991
Aries-Lee1991 commented Dec 16, 2021

In https://github.com/taosdata/TDengine/blob/develop/src/client/src/tscPrepare.c, Local variable loopCont is assigned only once, to a constant value, making it effectively constant throughout its scope. If this is not the intent, examine the logic to see if there is a missing assignment that would make loopCont not remain constant.

So the 1567th line should be removed.
![image](https://user-im

averelon
averelon commented Aug 7, 2020

The uncompensated temperature of the BMP180 is incorrectly converted to a 16-bit signed value, instead of a 32-bit signed value (long). Since the data is 16-bits wide and can therefore not be negative, the easy fix would be to do the following:

sip.js(1128): uncompensated = uint16(data[0], data[1]);

Please see page 15 of the manual of the BMP180 chip:
https://ae-bst.resource.bosch.com/media

juzhiyuan
juzhiyuan commented Dec 17, 2021

Improved or typo fixed.

Hi,

In our Chinese Documentations, we have breaking lines in original markdowns, e.g

`Plugin` 配置可直接绑定在 `Route` 上,也可以被绑定在 `Service` 或 `Consumer`上。而对于同一
个插件的配置,只能有一份是有效的,配置选择优先级总是 `Consumer` > `Route` > `Service`。

在 `conf/config.yaml` 中,可以声明本地 APISIX 节点都支持哪些插件。这是个白名单机制,不在该
白名单的插件配置,都将会被自动忽略。这个特性可用于临时关闭或打开特定插件,应对突发情况非常有效。
如果你想在现有插件的基础上新增插件,注意需要拷贝 `c
urh
jacobagilbert
jacobagilbert commented Sep 18, 2020

A common protocol structure is to have a header containing a length field, followed by data of length bytes, followed by additional protocol fields such as a CRC. If the length field is variable, the position of subsequent URH-specified protocol fields defined by fixed position will not be in the correct location.

I do not know the best way to address this, but quick and easy way to support

questdb
ysdede
ysdede commented Dec 16, 2021

Describe the bug

QuestDB throws an error if my query returns 0 rows when using SAMPLE BY. It works fine and responds 0 row found without SAMPLE BY.

My query (I run it on QuestDB web console directly)

SELECT ts, pair, side, round(nsum(size)) as size
FROM liquidations
WHERE pair = 'ETC-USDT-PERP' and side = 'sell' and size > 500
SAMPLE BY 1m
ALIGN TO CALENDAR WITH OFFSET '00:00'

This repository contains all the DSA (Data-Structures, Algorithms, 450 DSA by Love Babbar Bhaiya, FAANG Questions), Technical Subjects (OS + DBMS + SQL + CN + OOPs) Theory+Questions, FAANG Interview questions, and Miscellaneous Stuff (Programming MCQs, Puzzles, Aptitude, Reasoning). The Programming languages used for demonstration are C++, Python, and Java.

  • Updated Dec 9, 2021
  • Jupyter Notebook
microk8s
typoworx-de
typoworx-de commented Aug 31, 2021

While struggling around with ingress (#2546) I figured out some inconsistencies. For most k8s services it is possible to override args or configs. But for ingress this doesn't work.

It should be possible to customize enable.{my-service} and {my-service}.yaml by having a local copy in:
/var/snap/microk8s/current/microk8s-resources/

But this doesn't seem to work.

node-serialport
SVSagi
SVSagi commented Jul 30, 2018

Summary of Problem

Not able to open port with stopbits as 1.5

I am currently building a desktop client using electron, where the COM port receives data correctly for values: baudRate: 2400, dataBits: 7, stopBits: 1.5, parity: 'none'

I found from the node-serialport documentation, stopBits Must be one of these: 1 or 2. But, should 1.5 be supported as well? especially for old & slow

Improve this page

Add a description, image, and links to the iot topic page so that developers can more easily learn about it.

Curate this topic

Add this topic to your repo

To associate your repository with the iot topic, visit your repo's landing page and select "manage topics."

Learn more